When underwriters evaluate a commercial building, they generally examine four specific characteristics— construction, occupancy, protection and exposure (COPE).
It’s not uncommon for insureds to overlook how the underlying construction of their buildings impacts their insurance. However, when it comes to property coverage, the construction class is critical and can affect rates and the overall insurability of the structure.
As a result, it’s crucial to review the six different classifications of construction classes as outlined by the Insurance Services Office (ISO). In particular, insureds should understand what each class is, how to identify them and their advantages and disadvantages.
Frame ISO 1
Structures that fall under the frame classification have exterior walls made of wood or a light metal. However, the surface of those exterior walls can be any number of materials, including siding, brick veneer or metal. Roofs on a frame structure are wooden and often gabled. Furthermore, the height of frame buildings is limited to four stories.
Identification
When identifying frame structures, it’s important to avoid focusing too much on the exterior surface of the building, as things like brick veneers or metal cladding can cause confusion. Instead, try finding an unfinished part of the building.
If the exterior wall has wooden studs, you know your building falls under the frame classification. Additionally, examining the roof can help in your determination. If the roof is gabled or pitched, and made of combustible materials (e.g., shingles), your building can only fall under the frame or joisted masonry classifications.
Businesses that typically fall under a frame classification can include small apartment buildings, motels and small offices. In more industrial settings, some warehouses may fall under the frame classification. It’s also not uncommon for a manufacturing facility to put up a frame structure to create a low-cost storage solution.
Advantages and Disadvantages
Advantages and disadvantages of frame structures include:
- Advantages:
- Cost
- Ease of construction
- Ease of modification
- Disadvantages:
- Limited in terms of size
- High insurance rates
- May not be appropriate for some classes of businesses due to the high risk of fire and wind damage
Joisted Masonry ISO 2
Structures that fall under this classification have masonry exterior walls made of brick, concrete, stone, adobe or a similar material. The floors and roof deck of a joisted masonry building will be made of wood or other combustible material.
Roofs for joisted masonry buildings can be flat or gabled. The fire resistive rating of a joisted masonry building is at least one hour, and the height of these structures is limited to four stories.
Identification
Joisted masonry structures can be confused with both frame and masonry non-combustible buildings. When attempting to identify joisted masonry buildings, be mindful of exterior walls with a brick veneer. Buildings with these veneers will most certainly be frame structures.
If you are able to see the exposed underside of the roof, the presence of a wood decking indicates the structure falls under the joisted masonry classification. It’s important to note that, if masonry walls have floors and roof decks comprised of steel or noncombustible materials, the building will likely fall under the masonry noncombustible classification.
Businesses that often fall under the joisted masonry classification vary and can include small convenience stores, office buildings, apartments and warehouses.
Advantages and Disadvantages
Advantages and disadvantages of joisted masonry structures include:
- Advantages:
- Better fire protection than frame structures
- Structurally stable
- Potentially salvageable
- Disadvantages
- Roofs and floors are prone to fire damage
Noncombustible ISO 3
Noncombustible structures will have a steel frame, metal walls and a metal roof. Smaller buildings may not have interior columns, instead relying on the strength of the steel frame. Larger structures will have interior steel supports.
Despite being classified as noncombustible, these buildings may still have slow-burning insulation. Noncombustible structures may have a gabled or flat roof, both of which would be made of noncombustible materials.
Identification
Smaller, noncombustible buildings may look similar to a metal-clad frame building from the exterior. However, the inside of noncombustible structures will consist of a steel skeleton. Exterior walls are typically metal, but can be made of other noncombustible materials as well. Noncombustible buildings are common in the manufacturing and warehousing industry due to the increase risk of fires.
Advantages and Disadvantages
Advantages and disadvantages of noncombustible structures include:
- Advantages:
- Easy to build
- Fire-resistant
- Disadvantages:
- Increased risk of damage following a blaze, since fire weakens steel considerably
Masonry Noncombustible ISO 4
Masonry noncombustible (MNC) structures typically include masonry exterior walls that are comprised of concrete block or tilt-up, load-bearing walls. Floors of MNC structures will often be made of concrete.
MNC roofs are typically flat or low pitch, usually made with a steel deck. The roof will often be built up with gravel or bitumen. A steel structure may be used, but it will not be protected.
Identification
MNC structures may be confused with joisted masonry structures, as both have exterior masonry walls. To properly make the distinction, identifying the floor and roof deck materials is critical.
If the structure has a gabled roof with combustible materials (e.g., shingles), the building will not fall under the MNC classification, and is instead considered joisted masonry. If the roof is flat, the structure of the roof might not be easy to determine. If the roof is concrete and is equipped with fire-proofed steel, it may be a modified fire resistive structure. If the structure has exterior masonry walls supported with unprotected steel beams, the building is likely an MNC structure. Common examples of businesses that utilize MNC structures include manufacturing businesses, warehouses, strip malls and offices.
Advantages and Disadvantages
Advantages and disadvantages of MNC structures include:
- Advantages:
- More stable in a fire than a noncombustible structure (ISO 3)
- Disadvantages:
- Exposed steel on the roof and in the interior supports can weaken over time
Modified Fire Resistive ISO 5
Modified fire resistive (MFR) structures have protected steel. Fire resistive materials in MFR structures have a rating greater than one hour, but less than two hours. In MFR structures, exterior walls must be a minimum of 4 inches, and exposed steel beams may be sprayed with fire resistive materials.
Identification
An important component of identifying MFR structures is distinguishing them from MNC structures. A key difference between the two is that, in MFR structures, the steel exterior wall beams are protected by materials like concrete, plaster, clay, tile, brick and gypsum block. MFR structures are common in high-rise office and habitational buildings. When it comes to positively identifying these structures—and many of the higher construction classes in general—you really need to see the construction plans.
Advantages and Disadvantages
Advantages and disadvantages of MFR structures include:
- Advantages:
- Offer more protection than previous classes (ISO 1-4)
- Can be built taller than previous classes (ISO 1-4)
- Disadvantages:
- Expensive
- Less fire and wind protection than ISO 6 Reinforced Concrete Frames (Fire Resistive ISO 6)
Fire Resistive ISO 6
Fire resistive structures are similar to MFR structures. However, one of the key differences is that materials in fire resistive structures have a minimum fire rating two hours.
- Solid masonry walls at least 4 inches thick
- Hollow masonry walls at least 12 inches thick
- Hollow masonry walls less than 12 inches thick, but no less than 8 inches thick with a listed fireresistance rating of at least two hours
Identification
Advantages and Disadvantages
- Advantages:
- Can be built taller than all other classes
- More fire-resistant than all other classes
- More wind resistant than all other classes
- Disadvantages:
- Most expensive class
Mixed Classes
Continued Safety
This Coverage Insights is not intended to be exhaustive nor should any discussion or opinions be construed as legal advice. Readers should contact legal counsel or an insurance professional for appropriate advice. © 2020 Zywave, Inc. All rights reserved.